WARNING: The domain runtime MBean server has not been found after trying for 600 seconds

Error:  

WARNING: The domain runtime MBean server has not been found after trying for 600 seconds during startup of Admin Server. (I did face this error as part of OBIA 11.1.1.10 Installation)

Cause:  There can be several reasons for this (just highlighting few…)

  1.  Because of stuck thread
  2. You might have installed ODI, but has not configured it as part of installation (I did face this as part of OBIA 11.1.1.10 Installation)

Solution:

From ‘WLS admin console’ –> Click on ‘Servers’ –> Click on ‘Adminserver’ –> Click on ‘Tuning’ tab

Increase ‘Stuck Thread Max Time’ from ‘600’ to ‘900’ then restart application services and test the issue.